Basic properties

  • Mass of GFED: 4.5 kg
  • Protected volume: 1.0 m3
  • Extinguishing duration: 30 sec
  • Function of self-actuation
  • Can use on vehicles
  • Operation temperature: -45...+40°C
Download PDF
File size:
427.09 Kb
Ask a question

Ask a question about the
«Eol 3R100» gas fire extinguishing device

Your name
Country
Company
Your site
Your contact phone
Your e-mail
Your question

TO ORDER

To order
«Eol 3R100» gas fire extinguishing device

Your name
Country
Company
Your site
Your contact phone
Your e-mail
Quantity for order
Order description*

The device of gas fire extinguishing (hereinafter «GFED») «Eol 3R100» with axial gas outflow is designed to extinguish in conditionally sealed volume fires of the following Classes:

  • subclass A2 — combustion of solids not accompanied by smoldering;
  • Class B – combustion of flammable liquids;
  • Class C — combustion of gases;
  • Class E — fires occurring in rooms with cables, electrical installations and electrical equipment under voltage up to 1000V.

The predominant area of application – protection of boards with electrical equipment, cabinets with electronic equipment for server, process control systems, power plants and substations, compartments with electrical equipment, with electric motors, pumps and other technological equipment.

Relative humidity — no more than 98% at 25°C°. Operating temperature — from -45°C up to +40°С.

Gas produced by the operation of the device does not contain ozone-depleting substances.

The quantity and composition of the main products of combustion generated during operation of the device as a percentage by volume: CO2 — 63.3%; H2O — 25.63%; N2 -10.29%; CH4 — 0.66%; H2 — 0.094%; CO — 0.001%; NH3 — 0.0006%.

Specifications

The maximum volume of the conditionally sealed compartment in which GFAD provides extinguishing:
 — model fires of class B, m3 1,0
 — model fires of subclass A2, m3 1,0
Inertia response, sec, no more 10
Response time of the device at the lower limit operating temperature, sec, not more than 10
GFED working time (duration of supply of fire extinguishing gas) within the operating temperature, sec, no more than 45
The time (duration) of the supply of extinguishing gas (operation of the gas extinguishing device) at the lower limit operating temperature, s,  not more than 79
Overall dimensions, mm , no more:
 — length 328
 — diameter 89
Mass of GFED, kg 4,5±0,45
The distance along the length of the gas jet corresponding to temperatures, m, not more than:
 200 °С 0,03
 75 °С 0,10
Startup parameters (electric):
 — starting current value, A, not less than 0,5
 — start circuit resistance, Ohm 3,2÷4,2
 — pulse duration, MS, not more than 20
 — starting voltage, V, no more 26
 — guaranteed non-operation current (safe current control of the electrical circuit), A, not more than 0,1