RECOMMENDATIONS FOR FIRE PROTECTION OF TRAMS OF DIFFERENT BRANDS AND MANUFACTURERS.
Automatic fire detection and extinguishing system (AFDES) for PTMZ-71-153 trams
It consists of the following elements:
No. | Name | Drawing No. | Amount |
1 | Control system unit «BSU-02AM» | ПТКЛ.425532.004-01 | 1 |
2 | Fire Detector «FD» | ПТКЛ.425512.003 | 1 |
3 | Uninterruptable power source | ИБП 12.30-3/12-2Ач | 1 |
4 | Fire extinguishing means: Generators of fire extinguishing aerosol GEA «Doping 2.160p» | 1 |
Purpose:
BSU-02AM is designed for:
- Address automatic detection of emergency temperature rise of the environment in the protected compartments;
- The address light and sound warning of the driver about the emergency increase in the temperature of the environment and the malfunctions of the automated fire detection and extinguishing system AFDES elements;
- Running of fire extinguishing means in manual or automatic modes.
FD is designed for:
- Monitoring of the temperature of the environment in the protected compartment with the issuance of a signal about an emergency increase in temperature (this temperature is set).
The fire extinguishing means is designed for:
- Extinguishing of fires in conditionally hermetic volumes (compartments) of vehicles.
The fire extinguishing means are:
- Generator of fire extinguishing aerosol (GEA)
Automatic fire detection and extinguishing system (AFDES) for trams of the model «UKVZ-71-619»
It consists of the following elements:
No. | Name | Drawing No. | Amount |
1 | Control system unit «BSU-02AM» | ПТКЛ.425532.004-01 | 1 |
2 | Fire Detector «FD» | ПТКЛ.425512.003-02 | 1 |
3 | Fire Detector «FD» | ПТКЛ.425512.003-03 | 1 |
4 | Fire Detector «FD» | ПТКЛ.425512.003-04 | 1 |
5 | Fire Detector «FD» | ПТКЛ.425512.003-06 | 1 |
6 | Uninterruptable power source | ИБП 12/12-1Ач | 1 |
7 | Fire extinguishing means: Generators of fire extinguishing aerosol GEA «Doping 2.160p» | 5 |